| Sign In | Join Free | My chinalane.org | 
 | 
Brand Name : GFUVE
Model Number : GF106T
Certification : CE IEC ISO
Place of Origin : CHINA
MOQ : 1 Set
Price : Negotiable
Payment Terms : Western Union, MoneyGram, T/T, , L/C
Supply Ability : 200Sets/Month
Delivery Time : 3-4Weeks
Packaging Details : Alu-Box
NAME : CT PT ANALYZER
Accuracy : 0.2%, 0.5%
Power supply : AC 220V±10% or AC 110V±10%, 50/60Hz
Excitation voltage output : 0-2500Vrms
Excitation current output : 0-5Arms (20A peak-value)
Overall dimension (L x W x H) (mm) : 400 x 250 x 250
| I. Current Transformer (CT) | II. Voltage Transformer (PT) | 
|---|---|
| 1. Magnetization curve | 1. Excitation characteristic test | 
| 2. Transformation ratio test | 2. Transformation ratio test | 
| 3. Polarity | 3. Polarity | 
| 4. 5% and 10% error curve | 4. Withstand test of power frequency alternating current | 
| 5. Current Injecting | 5. Degauss | 
| 6. Degauss | 6. Calculation of knee point value | 
| 7. Withstand test of power frequency alternating current | 7. Actual secondary load test | 
| 8. Automatic calculation of excitation knee point value | 8. Resistance test | 
| 9. Actual secondary load test | |
| 10. Resistance test | |
| Electrical parameters | ||
|---|---|---|
| Accuracy | 0.2%, 0.5% | |
| Power supply | AC 220V±10% or AC 110V±10%, 50/60Hz | |
| Excitation voltage output | 0-2500Vrms, | |
| Excitation current output | 0-5Arms (20A peak-value) | |
| Large current output | 0-1000A | |
| Electrical parameters - continued | ||
| Accuracy | ≤0.5% (0.2%RD+0.3%RG) | |
| Secondary winding DC resistance measurement | Range | 0.1-300Ω | 
| Accuracy | ≤0.5% (0.2%RD+0.3%RG) | |
| Secondary actual load measurement | Range | 5VA-1000VA | 
| Accuracy | ≤0.5% (0.2%RD+0.3%RG)±0.1VA | |
| CT/PT phase error measurement | Accuracy | ±4min | 
| Resolution | 0.01min | |
| CT ratio error measurement | Range | ≤25000A/5A(5000A/1A) | 
| Accuracy | ≤0.5% | |
| PT ratio error measurement | Range | 1-500KV | 
| Accuracy | ≤0.5% | |
| Standards | ||
| Reference standards | GB1207-2006, GB1208-2006, GB16847-1997 IEC60044-1, IEC60044-6, IEC61869-2-2012 | |
| Safety standards | GB 4793.1-2007 | |
| EMC | EMC standard 89/336/EEC | |
| FCC Subpart B of Part 15 Class A | ||
| IEC 1000-4-2 /3 /4 /6 | ||
| Mechanical parameters | ||
| Overall dimension (L x W x H) (mm) | 400 x 250 x 250 | |
| Weight (kg) | ≤22 | |
| Environmental conditions | ||
| Relative humidity | 90RH% | |
| Operating temperature | -10°C to +40°C | |
| Altitude | ≤1000m | |


|   | 
| GF106T Transformer Test Instruments Simple Operation With Current / Voltage Generation Function Images | 
 1000A 2500V Automatic Portable CT PT Analyzer For Ratio & Phase Error Testing
                                                                                        
                                                        
                        
                        
                        
                                                            1000A 2500V Automatic Portable CT PT Analyzer For Ratio & Phase Error Testing
                                                    
                        
                     GF106 CT PT Analyzer Ct Pt Testing Equipment Type Printer Portable Accuracy 0.05
                                                                                    
                        
                        
                        
                                                            GF106 CT PT Analyzer Ct Pt Testing Equipment Type Printer Portable Accuracy 0.05
                                                    
                        
                     Automatic Smart IEC60044-1 Pt Potential Transformer
                                                                                        
                                                        
                        
                        
                        
                                                            Automatic Smart IEC60044-1 Pt Potential Transformer
                                                    
                        
                     4.8KG Weight CT PT Analyzer Voltage Transformer Analyzer 0.02% / 0.05% Accuracy
                                                                                        
                                                        
                        
                        
                        
                                                            4.8KG Weight CT PT Analyzer Voltage Transformer Analyzer 0.02% / 0.05% Accuracy
                                                    
                        
                     Portable GFUVE CT PT Analyzer Current Transformer Testing IEC60044-1
                                                                                        
                                                        
                        
                        
                        
                                                            Portable GFUVE CT PT Analyzer Current Transformer Testing IEC60044-1
                                                    
                        
                     GF1061 Ct Pt Analyzer Ct Pt Testing Equipment Electronic Power CE Certification
                                                                                        
                                                        
                        
                        
                        
                                                            GF1061 Ct Pt Analyzer Ct Pt Testing Equipment Electronic Power CE Certification
                                                    
                        
                     Electronic Power Power Quality Analyzer Portable Ct Testing Equipment 4kg Weight
                                                                                        
                                                        
                        
                        
                        
                                                            Electronic Power Power Quality Analyzer Portable Ct Testing Equipment 4kg Weight
                                                    
                        
                     Electronic Ct Test Equipment High Precision GF1061 Easy Operation For Lab
                                                                                        
                                                        
                        
                        
                        
                                                            Electronic Ct Test Equipment High Precision GF1061 Easy Operation For Lab
                                                    
                        
                     Portable Potential Current Transformer Testing Equipments With Ct Test Function
                                                                                        
                                                        
                        
                        
                        
                                                            Portable Potential Current Transformer Testing Equipments With Ct Test Function
                                                    
                        
                     Portable Voltage PT Power Transformer Testing Equipment With Polarity 4.8KG
                                                                                        
                                                        
                        
                        
                        
                                                            Portable Voltage PT Power Transformer Testing Equipment With Polarity 4.8KG